MONA MS database records for (LMST02010004)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
JP009509 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
JP011410 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
VF-NPL-QEHF001750 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF001751 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF001752 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF001753 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF001754 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF001755 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF001756 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF001757 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF001758 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF003250 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003251 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF003252 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
HMDB0000145_c_ms_2068 | Thermo Q Exactive HF | GC-MS | - | - | - | - | - |
HMDB0000145_c_ms_2090 | Thermo Q Exactive HF | GC-MS | - | - | - | - | - |
HMDB0000145_c_ms_2092 | Thermo Q Exactive HF | GC-MS | - | - | - | - | - |
BML81227 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
FFF00232 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00233 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00234 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00235 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00236 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00237 | API2000 | LC-APPI-QQ | - | - | [M+H]+ | positive | MS2 |
FFF00238 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00239 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00240 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00241 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00242 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00243 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00244 | API2000 | LC-APPI-QQ | - | - | [M+H]+,[M-H2O+H]+ | positive | MS1 |
FiehnHILIC001179 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
SM871901 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
BML00988 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML00996 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML01004 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
BML81225 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML81226 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
FiehnHILIC001590 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002688 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
VF-NPL-LTQ001285 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ001286 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ001287 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ001288 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ006379 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ006380 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS3 Composite |
HMDB0000145_ms_ms_218 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
HMDB0000145_ms_ms_219 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
HMDB0000145_ms_ms_220 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
CCMSLIB00000078231 | qTof | - | - | - | [M+H]+ | positive | MS2 |
HMDB0000145_ei_ms_1308 | qTof | - | - | - | - | - | - |