MONA MS database records for Clarithromycin (LMPK04000014)
BackMassbankID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
AU105301 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 30.8-46.2 eV | [M+H]+ | positive | MS2 |
AU105302 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU105303 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU105304 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU105305 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU105306 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU105307 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU105308 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU105309 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU105310 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU105311 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
CCMSLIB00000078998 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000078999 | qTof | - | - | - | [M+Na]+ | positive | MS2 |
EA019101 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA019102 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA019103 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA019104 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA019105 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA019106 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA019107 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA019108 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA019109 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA019110 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA019111 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA019112 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA019113 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA019114 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
FiehnHILIC000265 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001840 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002647 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
UF408502 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF408503 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF408504 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |