MONA MS database records for (LMPK13090005)

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
MoNA002319Waters QTOF SYNAPT-Electrospray Ionization (ESI)25 eV[M-H]negativeMS2
MoNA002621Waters QTOF SYNAPTQ Exactive HFElectrospray Ionization (ESI)-[M-H]-negativeMS2
CE000093LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFTESI35eV[M+H]+positiveMS2
CE000094LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFTESI45eV[M+H]+positiveMS2
CE000095LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFTESI55eV[M+H]+positiveMS2
CE000096LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFTESI70eV[M+H]+positiveMS2
CE000097LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFTESI--positiveMS1
EQ324101Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI15 (nominal)[M+H]+positiveMS2
EQ324103Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI45 (nominal)[M+H]+positiveMS2
EQ324105Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI75 (nominal)[M+H]+positiveMS2
EQ324106Q Exactive Orbitrap Thermo Sci...LC-ESI-QFTESI90 (nominal)[M+H]+positiveMS2
MetaboBASE0068impact HDLC-ESI-TOFESI--negative-
MetaboBASE0069impact HDLC-ESI-TOFESI50[M-H]-negativeMS2
MetaboBASE0070impact HDLC-ESI-TOFESI60[M-H]-negativeMS2
MetaboBASE0071impact HDLC-ESI-TOFESI20[M-H]-negativeMS2
MetaboBASE0072impact HDLC-ESI-TOFESI40[M-H]-negativeMS2
PB000641API QSTAR Pulsar iLC-ESI-QTOFESI15 eV[M+H]+positiveMS2
PB000642API QSTAR Pulsar iLC-ESI-QTOFESI25 eV[M+H]+positiveMS2
PB000643API QSTAR Pulsar iLC-ESI-QTOFESI40 eV[M+H]+positiveMS2
PB000661API QSTAR Pulsar iLC-ESI-QTOFESI55 eV[M+H]+positiveMS2
PB002421API QSTAR Pulsar iLC-ESI-QTOFESI15 eV[M-H]-negativeMS2
PB002422API QSTAR Pulsar iLC-ESI-QTOFESI25 eV[M-H]-negativeMS2
PB002423API QSTAR Pulsar iLC-ESI-QTOFESI40 eV[M-H]-negativeMS2
PB002424API QSTAR Pulsar iLC-ESI-QTOFESI55 eV[M-H]-negativeMS2
PB003661TSQ QUANTUM AMLC-ESI-QQESI20 eV[M-H]-negativeMS2
PB003662TSQ QUANTUM AMLC-ESI-QQESI25 eV[M-H]-negativeMS2
PB006261micrOTOF-QLC-ESI-QTOFESI10 eV[M+H]+positiveMS2
PB006262micrOTOF-QLC-ESI-QTOFESI15 eV[M+H]+positiveMS2
PB006263micrOTOF-QLC-ESI-QTOFESI20 eV[M+H]+positiveMS2
PS078901TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS078902TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS078903TQD, WatersFlow-injection QqQ/MSESI30[M+H]+positiveMS2
PS078907TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS078908TQD, WatersFlow-injection QqQ/MSESI20[M-H]-negativeMS2
PS078909TQD, WatersFlow-injection QqQ/MSESI30[M-H]-negativeMS2
BML00641Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-10 ev[M+H]+positiveMS2
BML00673Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-10 ev[M-H]-negativeMS2
BML00681Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-20 ev[M-H]-negativeMS2
BML00689Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-40 ev[M-H]-negativeMS2
BML82055Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---positiveMS1
BML82056Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---negativeMS1
BML82057Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF---positiveMS1
BML82058Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF---negativeMS1
FiehnHILIC000733Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
FiehnHILIC001487Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
FiehnHILIC002299SCIEX TripleTOF 6600LC-ESI-QTOF-35 eV[M+H]+positiveMS2
FiehnHILIC003022SCIEX TripleTOF 6600LC-ESI-QTOF-35 eV[M-H]-negativeMS2
FiehnLib000620Leco Pegasus IVGC-EI-TOF---positiveMS1
FiehnLib000621Leco Pegasus IVGC-EI-TOF---positiveMS1
HMDB0003747_c_ms_2088Leco Pegasus IVGC-MS-----
HMDB0003747_ms_ms_285978Leco Pegasus IVESI-TOF---negative-
HMDB0003747_ms_ms_285979Leco Pegasus IVESI-TOF---negative-
HMDB0003747_ms_ms_285980Leco Pegasus IVESI-TOF---negative-
HMDB0003747_ms_ms_285981Leco Pegasus IVESI-TOF---negative-
HMDB0003747_ms_ms_285982Leco Pegasus IVESI-TOF---negative-
RIKENPlaSMA002554Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002560Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002566Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002572Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA002578Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002584Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002590Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002596Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA002602Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002608Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002614Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002620Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
VF-NPL-LTQ001907Thermo Finnigan LTQLinear Ion Trap-35M-HnegativeMS2
VF-NPL-LTQ001908Thermo Finnigan LTQLinear Ion Trap-35M-HnegativeMS2-MS3 Composite
VF-NPL-LTQ006621Thermo Finnigan LTQLinear Ion Trap-35M-HnegativeMS2
VF-NPL-LTQ006622Thermo Finnigan LTQLinear Ion Trap-35M-HnegativeMS2-MS3 Composite
VF-NPL-QEHF004777Thermo Q Exactive HFESI-QFT-35HCD[M-H]-negativeMS2
VF-NPL-QEHF004778Thermo Q Exactive HFESI-QFT-45HCD[M-H]-negativeMS2
VF-NPL-QEHF004779Thermo Q Exactive HFESI-QFT-65HCD[M-H]-negativeMS2
VF-NPL-QEHF004780Thermo Q Exactive HFESI-QFT-35HCD[M+Na]+positiveMS2
VF-NPL-QEHF004781Thermo Q Exactive HFESI-QFT-45HCD[M+Na]+positiveMS2
VF-NPL-QEHF004782Thermo Q Exactive HFESI-QFT-65HCD[M+Na]+positiveMS2
VF-NPL-QEHF004783Thermo Q Exactive HFESI-QFT-35HCD[M+K]+positiveMS2
VF-NPL-QEHF004784Thermo Q Exactive HFESI-QFT-45HCD[M+K]+positiveMS2
VF-NPL-QEHF004785Thermo Q Exactive HFESI-QFT-65HCD[M+K]+positiveMS2
VF-NPL-QEHF004786Thermo Q Exactive HFESI-QFT-35HCD[M+NH4]+positiveMS2
VF-NPL-QEHF004787Thermo Q Exactive HFESI-QFT-45HCD[M+NH4]+positiveMS2
VF-NPL-QEHF004788Thermo Q Exactive HFESI-QFT-65HCD[M+NH4]+positiveMS2
VF-NPL-QEHF004789Thermo Q Exactive HFESI-QFT-35HCD[M+H]+positiveMS2
VF-NPL-QEHF004790Thermo Q Exactive HFESI-QFT-45HCD[M+H]+positiveMS2
VF-NPL-QEHF004791Thermo Q Exactive HFESI-QFT-65HCD[M+H]+positiveMS2