MONA MS database records for (LMST02020023)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
BML81170 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML81172 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
FFF00192 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+,[M-H2O+H]+ | positive | MS1 |
CCMSLIB00000084793 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FFF00180 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00181 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00182 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00183 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00184 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00185 | API2000 | LC-APPI-QQ | - | - | [M-H2O+H]+ | positive | MS2 |
FFF00186 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+ | positive | MS2 |
FFF00187 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+ | positive | MS2 |
FFF00188 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+ | positive | MS2 |
FFF00189 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+ | positive | MS2 |
FFF00190 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+ | positive | MS2 |
FFF00191 | API2000 | LC-APPI-QQ | - | - | [M-2H2O+H]+ | positive | MS2 |
UF416801 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF416803 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF416804 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
VF-NPL-LTQ007133 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-QEHF013918 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013919 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013920 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013921 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013922 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013923 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-LTQ007134 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS4 Composite |
HMDB0000365_ms_ms_582 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
HMDB0000365_ms_ms_583 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |
HMDB0000365_ms_ms_584 | Thermo Finnigan LTQ | Quattro_QQQ | - | - | - | positive | - |