Massbank ID |
Instrument |
Inst. type |
MS type |
Collision energy |
Ion type |
Ion mode |
MS level |
PR040050 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [2M-H]- | negative | MS2 |
PR040052 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [2M-H]- | negative | MS2 |
VF-NPL-LTQ000019 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+Cl | negative | MS2 |
VF-NPL-LTQ000020 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+Cl | negative | MS2-MS5 Composite |
BML00143 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML01862 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
CCMSLIB00000077221 | Ion Trap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00004684187 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00004684190 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
FiehnHILIC002955 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FIO00277 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
FIO00278 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
FIO00279 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
FIO00280 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
FIO00281 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M-H]- | negative | MS2 |
MetaboBASE0391 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0397 | impact HD | LC-ESI-TOF | ESI | 10 | [M-H]- | negative | MS2 |
MetaboBASE0399 | impact HD | LC-ESI-TOF | ESI | 40 | [M-H]- | negative | MS2 |
MoNA003267 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | Electrospray Ionization (ESI) | Stepped (NCE 20-30-40%) | [M-H]- | negative | MS2 |
PB002409 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M-H]- | negative | MS2 |
PB002410 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M-H]- | negative | MS2 |
PB002411 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
PB002412 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M-H]- | negative | MS2 |
PB004101 | TSQ 7000 | LC-ESI-QQ | ESI | 20 eV | [M-H]- | negative | MS2 |
PB004102 | TSQ 7000 | LC-ESI-QQ | ESI | 25 eV | [M-H]- | negative | MS2 |
PB004103 | TSQ 7000 | LC-ESI-QQ | ESI | 30 eV | [M-H]- | negative | MS2 |
PM000419 | API 3000 | QqQ | ESI | - | [M-H]- | negative | MS2 |
PN000110 | micrOTOF-Q | ESI-TOF | ESI | 25 eV | [M-H]- | negative | MS2 |
PR040049 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M-H]- | negative | MS2 |
PR040051 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
PR100646 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PS040907 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS040908 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PT204090 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
RIKENPlaSMA006494 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006498 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006503 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006508 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006513 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006517 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006522 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006527 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006532 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006537 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006542 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006547 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RP012411 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP012412 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
RP012413 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
TY000166 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | [M-H]- | negative | MS2 |
VF-NPL-QEHF000061 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000062 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000063 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000664 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000665 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000666 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014431 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014432 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014433 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QTOF002153 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002154 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002155 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
CCMSLIB00000077993 | Ion Trap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578413 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000848653 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
CE000168 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
CE000169 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 45eV | [M+H]+ | positive | MS2 |
CE000170 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 55eV | [M+H]+ | positive | MS2 |
FIO00272 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO00273 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO00274 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO00275 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
FIO00276 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
ML005401 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
PB000181 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB000201 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB000202 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB000221 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M+H]+ | positive | MS2 |
PB004083 | TSQ QUANTUM AM | LC-ESI-QQ | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB004084 | TSQ QUANTUM AM | LC-ESI-QQ | ESI | 30 eV | [M+H]+ | positive | MS2 |
PB004085 | TSQ QUANTUM AM | LC-ESI-QQ | ESI | 35 eV | [M+H]+ | positive | MS2 |
PB006204 | micrOTOF-Q | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB006205 | micrOTOF-Q | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB006206 | micrOTOF-Q | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PM005333 | Quattro II | QqQ | ESI | 30V | [M+H]+ | positive | MS2 |
PM018401 | LCQ Duo | QIT | ESI | 20->60% | [M+H]+ | positive | MS2 |
PN000111 | micrOTOF-Q | ESI-TOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PR020008 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 5.0 V | [M+H]+ | positive | MS1 |
PR040053 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PR040054 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M+H]+ | positive | MS2 |
PR100233 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PS040901 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS040902 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS040903 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PT104090 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
RIKENPlaSMA002802 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002807 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002812 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002817 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002822 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002827 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002832 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002837 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002842 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002847 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002852 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002857 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RP012401 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP012402 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP012403 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000064 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000065 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000066 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000667 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000668 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000669 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014434 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014435 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014436 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002156 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002157 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002158 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000319 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000320 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ000321 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000322 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ007769 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ007770 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ007771 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ007772 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ007239 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ007240 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS5 Composite |
VF-NPL-LTQ007241 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | negative | MS2 |
VF-NPL-LTQ007242 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | negative | MS2-MS5 Composite |
BML82025 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML82026 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
CE000171 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | - | - | positive | MS1 |
HMDB0005794_c_ms_2261 | LTQ Orbitrap XL, Thermo Scient... | GC-MS | - | - | - | - | - |
HMDB0005794_ms_ms_2445 | LTQ Orbitrap XL, Thermo Scient... | Quattro_QQQ | - | - | - | positive | - |
HMDB0005794_ms_ms_2446 | LTQ Orbitrap XL, Thermo Scient... | Quattro_QQQ | - | - | - | positive | - |
HMDB0005794_ms_ms_2447 | LTQ Orbitrap XL, Thermo Scient... | Quattro_QQQ | - | - | - | positive | - |
HMDB0005794_ms_ms_285598 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285599 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285600 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285601 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285602 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285603 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285604 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285605 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285606 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285607 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
HMDB0005794_ms_ms_285608 | LTQ Orbitrap XL, Thermo Scient... | ESI-TOF | - | - | - | negative | - |
MetaboBASE0388 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | MS2 |
MetaboBASE0389 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
MetaboBASE0390 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
MetaboBASE0392 | impact HD | LC-ESI-TOF | ESI | 30 | - | negative | MS2 |
MetaboBASE0393 | impact HD | LC-ESI-TOF | ESI | 20 | - | negative | MS2 |
MetaboBASE0394 | impact HD | LC-ESI-TOF | ESI | 40 | - | negative | MS2 |
MetaboBASE0395 | impact HD | LC-ESI-TOF | ESI | 50 | - | negative | MS2 |
MetaboBASE0396 | impact HD | LC-ESI-TOF | ESI | 30 | - | negative | MS2 |
MetaboBASE0398 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
TY000164 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | - | positive | MS1 |
TY000165 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | - | negative | MS1 |