MONA MS database records for (LMPK12120096)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
HMDB0037316_ms_ms_285960 | ESI-TOF | - | - | - | negative | - | |
HMDB0037316_ms_ms_285961 | ESI-TOF | - | - | - | negative | - | |
MetaboBASE0261 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0262 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
PM002115 | LCQ | QIT | ESI | 30->34% | [M-H]- | negative | MS2 |
RIKENPlaSMA006367 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006373 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006379 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006385 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006390 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006395 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006401 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006407 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006412 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006418 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006424 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006430 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
VF-NPL-LTQ002993 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ002994 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-QEHF010738 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF010739 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF010740 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011758 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011759 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011760 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QTOF001559 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001560 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001561 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
CCMSLIB00000078807 | qTOF | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000848336 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
FiehnLib000920 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
PM008227 | Esquire | QIT | ESI | 4.0V | - | positive | MS2 |
RIKENPlaSMA002697 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002702 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002707 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002712 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002717 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002722 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002727 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002732 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002737 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002742 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002747 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002752 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
VF-NPL-LTQ002991 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ002992 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS4 Composite |
VF-NPL-QEHF010741 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF010742 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF010743 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF010744 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF010745 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF010746 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF010747 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF010748 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF010749 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF010750 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF010751 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF010752 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF011761 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF011762 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF011763 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001562 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001563 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001564 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |