MONA MS database records for (LMFA01170107)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PS104401 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS104407 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
KO001427 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO001428 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO001429 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
VF-NPL-LTQ006637 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | -- | negative | MS2 |
VF-NPL-LTQ006638 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | -- | negative | MS2-MS3 Composite |
VF-NPL-QEHF011359 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011362 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF011365 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF011368 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF011371 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
KO001430 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QEHF011360 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011363 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF011366 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF011369 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF011372 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
KO001431 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
VF-NPL-QEHF011361 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF011364 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF011367 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF011370 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF011373 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
FiehnHILIC001337 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
PT210440 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PR100877 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
FiehnLib000398 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0000639_c_ms_1748 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0000639_ms_ms_873 | Leco Pegasus IV | Quattro_QQQ | - | - | - | negative | - |
HMDB0000639_ms_ms_874 | Leco Pegasus IV | Quattro_QQQ | - | - | - | negative | - |
HMDB0000639_ms_ms_875 | Leco Pegasus IV | Quattro_QQQ | - | - | - | negative | - |