MONA MS database records for Eriodictyol (LMPK12140002)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PM010508 | Esquire | QIT | ESI | - | [M-H]- | negative | MS2 |
MetaboBASE0464 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | MS2 |
MetaboBASE0465 | impact HD | LC-ESI-TOF | ESI | 20 | - | negative | MS2 |
MetaboBASE0466 | impact HD | LC-ESI-TOF | ESI | 30 | - | negative | MS2 |
MetaboBASE0469 | impact HD | LC-ESI-TOF | ESI | 40 | - | negative | MS2 |
MetaboBASE0467 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
MetaboBASE0468 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
PM001110 | LCQ | QIT | ESI | 45% | [M-H]- | negative | MS2 |
PT203980 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT103980 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PS039807 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS039808 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS039809 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M-H]- | negative | MS2 |
PS039810 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M-H]- | negative | MS2 |
PS039811 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M-H]- | negative | MS2 |
PS039812 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M-H]- | negative | MS2 |
PS039801 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS039802 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS039803 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS039804 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS039805 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PR040014 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [2M-H]- | negative | MS2 |
PR040012 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [2M-H]- | negative | MS2 |
PR040013 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
PR040011 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M-H]- | negative | MS2 |
PR100639 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR020015 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 5.0 V | [M+H]+ | positive | MS1 |
PR040015 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PR040016 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 eV | [M+H]+ | positive | MS2 |
PR100226 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
RIKENPlaSMA006152 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006157 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006172 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006177 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006192 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006197 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006162 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006182 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006202 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006167 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006187 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006207 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA002483 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002488 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002506 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002512 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002530 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002535 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002494 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002518 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002541 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002500 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002524 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002547 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
HMDB0005810_ms_ms_285775 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0005810_ms_ms_285776 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0005810_ms_ms_285777 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0005810_ms_ms_285778 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0005810_ms_ms_285779 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0005810_ms_ms_285780 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |