MONA MS database records for Chrysin (LMPK12110189)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MetaboBASE0012 | impact HD | LC-ESI-TOF | ESI | 26.25 | [M-H]- | negative | MS2 |
MetaboBASE0013 | impact HD | LC-ESI-TOF | ESI | 40 | [M-H]- | negative | MS2 |
MetaboBASE0011 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
PM001104 | LCQ | QIT | ESI | 45% | [M-H]- | negative | MS2 |
FIO00028 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
FIO00029 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
FIO00030 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
FIO00031 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
FIO00032 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M-H]- | negative | MS2 |
FIO00023 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO00024 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO00025 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO00026 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
FIO00027 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
BML01063 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML01066 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML01069 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
BML80936 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML80938 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML01054 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML01057 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML01060 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML80935 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML80937 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
VF-NPL-QTOF000659 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF000660 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF000661 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF000662 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF000663 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF000664 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
FiehnLib000489 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000848300 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000077227 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000078873 | qTof | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000381 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ000382 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ007269 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | negative | MS2 |
VF-NPL-LTQ007270 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | negative | MS2-MS5 Composite |
VF-NPL-LTQ000379 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ003825 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ000380 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ003826 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ007267 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ007268 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS4 Composite |
VF-NPL-QEHF014188 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014473 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014189 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014474 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014190 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014475 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF014191 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014476 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014192 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014477 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014193 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF014478 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
RIKENPlaSMA007094 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007097 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007104 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007107 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007115 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007118 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007099 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007110 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007121 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007101 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007112 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007124 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA003379 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003382 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003391 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003394 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003402 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003405 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003385 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003397 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003408 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003388 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003399 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003410 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
HMDB0036619_ms_ms_285640 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0036619_ms_ms_285641 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0036619_ms_ms_285642 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0036619_c_ms_2120 | Waters Xevo G2 Q-Tof | GC-MS | - | - | - | - | - |