MONA MS database records for Erythromycin (LMPK04000006)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA001199 | Thermo Q Exactive HF | - | Electrospray Ionization (ESI) | NCE 20% | [M+Hac-H]- | negative | MS2 |
MoNA001198 | Thermo Q Exactive HF | - | Electrospray Ionization (ESI) | NCE 20% | [M+H]+ | positive | MS2 |
AU105407 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU105402 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU105408 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU105403 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU105409 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU105404 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU105410 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU105405 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU105411 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
CE000001 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
CE000002 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 45eV | [M+H]+ | positive | MS2 |
CE000003 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 55eV | [M+H]+ | positive | MS2 |
CE000004 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 70eV | [M+H]+ | positive | MS2 |
CE000005 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | - | - | positive | MS1 |
EA018902 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA018908 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
EA018903 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
EA018909 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
UF407403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
EA018901 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA018914 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
EA018904 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
EA018910 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
UF407401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF407404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
EA018905 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA018911 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
EA018906 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
EA018912 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
UF407402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
EA018907 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
EA018913 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
PB005801 | micrOTOF-Q | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB005802 | micrOTOF-Q | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB005803 | micrOTOF-Q | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PB005804 | micrOTOF-Q | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
WA002287 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
WA002281 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA002282 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA002283 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA002284 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA002285 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA002286 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
BML81201 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML81200 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
CCMSLIB00000075306 | Hybrid FT | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000075305 | Ion Trap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00003739948 | qTof | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ006443 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-LTQ006444 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS5 Composite |
VF-NPL-QEHF003379 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003380 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF003381 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |